Diagnostic performance of endoscopic ultrasound-guided fine needle aspiration of pancreatobiliary lesions with in-room pathologist
DOI:
https://doi.org/10.22516/25007440.628Keywords:
Endoscopic ultrasound, Pancreatic neoplasms, Biliary tract cancer, Fine needle aspirationAbstract
Introduction: Endoscopic ultrasound with fine-needle aspiration (EUS-FNA) of pancreatobiliary neoplastic lesions usually has a high performance that depends on the characteristics of the lesion, technical aspects, and expertise of the endoscopist. One of the least studied factors is rapid on-site evaluation with a pathologist in the room.
Objective: To perform EUS-FNA with a pathologist in the endoscopy room to reduce the number of passes, the rate of inadequate samples and the need to repeat the procedure.
Material and methods: Observational retrospective study with a prospective data collection approach from January 2018 to June 2019 of adult patients undergoing EUS-FNA. The samples obtained were spread and evaluated in endoscopy rooms by a pathologist with Diff-Quick stain, and when a sufficient sample was obtained, it was sent in a vial with formalin for cell block and/or biopsy.
Results: 48 pancreatobiliary EUS-FNA were performed in individuals with a median age of 64 years. The most frequent indication was aspiration due to pancreatic mass (71%); 35 malignancies were diagnosed (77% were adenocarcinomas and 14% were neuroendocrine tumors). The median size of the lesions was 28mm, and the average number of passes was 3. Diagnostic results were obtained in 89% vs. 11% of false negatives. There was 1 minor complication (2.1%), which was abdominal pain.
Conclusions: EUS-FNA with an in-room pathologist has a high diagnostic performance, with few false negative results. Also, a lower median number of passes is required, minimizing the risks of the procedure and the need for repeating it.
Downloads
References
Bhutani MS, Koduru P, Joshi V, Saxena P, Suzuki R, Irisawa A, et al. The role of endoscopic ultrasound in pancreatic cancer screening. Endosc Ultrasound. 2016;5(1):8-16. https://doi.org/10.4103/2303-9027.175876
Uehara H, Ikezawa K, Kawada N, Fukutake N, Katayama K, Takakura R, et al. Diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration for suspected pancreatic malignancy in relation to the size of lesions. J Gastroenterol Hepatol. 2011;26(8):1256-61. https://doi.org/10.1111/j.1440-1746.2011.06747.x
Hewitt MJ, McPhail MJ, Possamai L, Dhar A, Vlavianos P, Monahan KJ. EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysis. Gastrointest Endosc. 2012;75(2):319-31. https://doi.org/10.1016/j.gie.2011.08.049
Ayres LR, Kmiotek EK, Lam E, Telford JJ. A Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Fine-Needle Biopsy in the Diagnosis of Solid Pancreatic Lesions. Can J Gastroenterol Hepatol. 2018;2018:1415062. https://doi.org/10.1155/2018/1415062
Iglesias-Garcia J, Dominguez-Munoz JE, Abdulkader I, Larino-Noia J, Eugenyeva E, Lozano-Leon A, et al. Influence of on-site cytopathology evaluation on the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic masses. Am J Gastroenterol. 2011;106(9):1705-10. https://doi.org/10.1038/ajg.2011.119
Schmidt RL, Walker BS, Howard K, Layfield LJ, Adler DG. Rapid on-site evaluation reduces needle passes in endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions: a risk-benefit analysis. Dig Dis Sci. 2013;58(11):3280-6. https://doi.org/10.1007/s10620-013-2750-6
Facciorusso A, Stasi E, Di Maso M, Serviddio G, Ali Hussein MS, Muscatiello N. Endoscopic ultrasound-guided fine needle aspiration of pancreatic lesions with 22 versus 25 Gauge needles: A meta-analysis. United European Gastroenterol J. 2017;5(6):846-853. https://doi.org/10.1177/2050640616680972
Paksoy N, Ozbek B. Cytopathologist-performed and ultrasound-guided fine needle aspiration cytology enhances diagnostic accuracy and avoids pitfalls: An overview of 20 years of personal experience with a selection of didactic cases. Cytojournal. 2018;15:8. https://doi.org/10.4103/cytojournal.cytojournal_20_17
Alsibai KD, Denis B, Bottlaender J, Kleinclaus I, Straub P, Fabre M. Impact of cytopathologist expert on diagnosis and treatment of pancreatic lesions in current clinical practice. A series of 106 endoscopic ultrasound-guided fine needle aspirations. Cytopathology. 2006;17(1):18-26. https://doi.org/10.1111/j.1365-2303.2006.00312.x
Rodrigues-Pinto E, Jalaj S, Grimm IS, Baron TH. Impact of EUS-guided fine-needle biopsy sampling with a new core needle on the need for onsite cytopathologic assessment: a preliminary study. Gastrointest Endosc. 2016;84(6):1040-1046. https://doi.org/10.1016/j.gie.2016.06.034

Downloads
Published
How to Cite
Issue
Section
License
Aquellos autores/as que tengan publicaciones con esta revista, aceptan los términos siguientes:
Los autores/as ceden sus derechos de autor y garantizarán a la revista el derecho de primera publicación de su obra, el cuál estará simultáneamente sujeto a la Licencia de reconocimiento de Creative Commons que permite a terceros compartir la obra siempre que se indique su autor y su primera publicación en esta revista.
Los contenidos están protegidos bajo una licencia de Creative Commons Reconocimiento-NoComercial-SinObraDerivada 4.0 Internacional.

Article metrics | |
---|---|
Abstract views | |
Galley vies | |
PDF Views | |
HTML views | |
Other views |